Building and Codes Administration » Building and Structural » » Codes and Regulations » Residential Decks Deck Requirements: SONO TUBES: Minimum 8” diameter and 48” below grade with mushroom footing. POSTS: 4”x 4” min, secured to base and beam. Suggest max 8’ spacing. LEDGER: Flash behind and above & bolt to house @ 16” max. GUARD RAILS: Required on open side of stairs as well as deck. Min 36” high, max 4” spacing between balusters. A graspable handrail is required on one side, 30” to 38” high. STAIRS: Max rise 7 ¾”x 10” run. FRAME: Pressure treated or naturally durable species. Floor Joist Spans @ 16" OC 2"x6" = 8'8" 2" x 8" = 11'3" 2" x 10" = 13'7" 2" x 12" = 15'11" Beam Allowable Load (Allow 55#/sq.ft.)
Check the Building Permit Application Permits are issued 8:30-9:30 a.m. or 4:00-5:00 p.m. ONLY. Stair Requirements and Guidelines
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|